  172 172 rotary type power switch with encoder rotary type with encoder sdkz circuit arrangement other positions operating direction product no. drawing no. dpst 103 n 63n 7. 53 n 103 n 7. 53 n 103 n from "off" position to "on" position torque 143 n 12 3 n 143 n positions 15 16 19 21 24 25 vertical mounting method pc board terminal configuration straight minimum order unitpcs. japan min 288 288 sdkz1f0200 sdkz1g0200 sdkz1k0200 SDKZ1M0200 sdkz1q0200 sdkz1r0200 1 2 product line ratings and safety standards items specifications maximum rating power 166a 250v ac 146a 250v ac maximum rating encoder 0.1a 12v dc contact resistance encoder initial / after life test 1 max. / 1 max. operating power 10,000 cycles operating life encoder 30,000 cycles refer to p.176 for soldering conditions. packing specifications tray number of packages pcs. export package measurements mm 1 case /japan 1 case /export packing 288 288 4 11 3 11 2 1 7 rotary type push type slide type rocker type detector detector slide slide push push rotary rotary power power dual-in-line package type dual-in-line package type
173 173 sdkzrotary type with encoder dimensions unit:mm                 " "    no. style pc board mounting hole dimensions pc board mounting hole dimensions 1 2 rotary type push type slide type rocker type detector detector slide slide push push rotary rotary power power dual-in-line package type dual-in-line package type
174 174 rotary type with encoder sdkz standard code 27.25$ 27.25$ 13-23.5$ 1 12 11 10 9 8 7 6 5 4 3 2 15 14 13 circuit diagram(power switch) 12 1a 2a 34 56 8 code pos term 123 4 56789 10 11 12 13 14 15 power contacts1-2 condification contact3 condification contact4 condification contact5 condification contact6 sdkz1f0200 term 16-22.5 $ circuit diagram(power switch) 12 1a 2a 34 56 8 1 6 1 2 3 4 5 6 7 8 9 1 0 1 1 2 1 3 1 4 1 5 code pos 123 45 6789 10 11 12 13 14 15 16 power contacts1-2 condification contact3 condification contact4 condification contact5 condification contact6 sdkz1g0200 1 2 1a 2a 3 4 5 67 8 4-30$ 16-15 $ 23 24 22 21 20 19 18 17 16 15 13 11 12 14 10 9 8 7 6 5 4 3 1 2 code term pos 123 4 56789 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 power contacts1-2 condification contact3 condification contact4 condification contact5 condification contact6 condification contact7 circuit diagram(power switch) sdkz1k0200 12 1a 2a 34 56 78 21 20 19 18 17 16 15 12 13 14 11 10 8 7 6 5 4 3 2 code term pos 123 45 6789 10 11 12 13 14 15 16 17 18 19 20 21 power contacts1-2 condification contact3 condification contact4 condification contact5 condification contact6 condification contact7 9 1 circuit diagram(power switch) SDKZ1M0200 24-15 $ 1 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 12 1a 2a 34 56 78 code term pos 123 45 6789 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 power contacts1-2 condification contact3 condification contact4 condification contact5 condification contact6 condification contact7 circuit diagram(power switch) sdkz1q0200 circuit diagram(power switch) 12 1a 2a 34 5678 2-19$ 23-14 $ 24 25 23 22 21 19 20 18 17 16 14 15 13 12 11 10 9 8 7 6 5 4 3 2 1 code term pos 123 4 56789 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 power contacts1-2 condification contact3 condification contact4 condification contact5 condification contact6 condification contact7 sdkz1r0200 rotary type push type slide type rocker type detector detector slide slide push push rotary rotary power power dual-in-line package type dual-in-line package type
159 159 type rocker slide rotary series sddjf1a sdkp sdkz sdde photo rating 8a / 128a 250v? 10 (6) / 250? 5ra 250v ac ps: 166a 250v ac 146a 250v ac ac switch: 1a / 16a 250v ? dc switch: 20ma 12v dc dc: 0.1a 12v dc encoders: 0.1a 12v dc operating life 10,000cycles 10 0 c y c l e s 10,000cyclespower ac switch: 10,000 cycles dc switch: 10,000 cycles 30,000cyclesencoder 10a 250v ac without load 16a 250v ac power 0.1a 12v dc encoder encoder 30,000 cycles travel mm 4.6 6 endless push switches: 1.85mm encoders: 360 360 rotation features with encoders circuit ac switch, dc switch, with encoder operating temperature range ?10 to 55 ?10 to 60 ?10 to 70 0 to 85 automotive use life cycle (availability) electrical performance contact resistance 10 0 m m a x . 1 0 0 m m a x . p o w e r ac switch: 100m max. dc switch: 500m max. encoder: 1 max. 1 m ax. encoder insulation resistance 500m m in. 500v dc 500m m in. 500v dc power ac switch: 100m min. 500v dc d c s w i t c h : 10 0 m m i n . 10 0 v d c encoder: 100m min. 100v dc 10 0 m m i n . 10 0 v d c encoder voltage proof 2,000v ac for 1minute 2,000v ac for 1minute power ac switch: 2,000v ac for 1 minute dc switch: 100v ac for 1 minute encoder: 100v ac for 1 minute 10 0 v a c f o r 1m i n u t e encoder mechanical performance terminal strength 50n for 1minute 10 n f o r 1m i n u t e 2 0 n p o w e r ac switch: 5n for 1 minute dc switch: 5n for 30s encoder: 5n for 1 minute 5n encoder actuator strength operating direction 25n 50n encoder: 100v 10 0 n perpendicular direction 25n 50n 30n 30n (retract direction) environmental performance cold ?20 96h ?40 240h dry heat 85 96h 85 24 0h damp heat 40, 9 0 to 95%rh 96h 40, 9 0 to 95%rh 240h page 17 0 171 17 2 17 5 power switches soldering conditions ?????????????????????????????????????????????? 176 power switches cautions ???????????????????????????????????????????????????? 176 power switches safety standard ???????????????????????????????????????????????? 176 note indicates applicability to some products in the series. push type detector detector slide slide push push rotary rotary power power dual-in-line package type dual-in-line package type rocker type slide type rotary type
176 176 1. safety standards outline safety standards are established by a country or an organization representing it to protect general users from electrical shock and fire hazards. it establishes standards for electrical devices and components. for electrical equipment manufacturers, utilizing switches that have been safety-approved ensures the safety of the switch. the use of a safety-approved switch also simplifies at least one part of the process of obtaining certification by safety testing. 2. major safety standards 1 electrical appliance and material safety law the conventional [electrical appliance and material control law] has changed to [electrical appliance and material safety law] and has been enforced since april 1, 2001. electrical appliances are categorized into special electric appliances and partsformerly class aand electrical appliances other than the special electric appliances formerly class b. special electric appliances are required to receive goodness of fit test at a certified test agency and to store the certificate. also, penal provisions have been reinforced . 2 ul underwriters laboratories inc. underwriters laboratories inc.ulis the american safety approving organization. its purpose is to ensure consumer safety and protect them from fire hazards. state law requires that equipment to be exported to the united states utilize ul approved power switches or power switches meeting ul standards and capable of passing ul tests. sddje, sddjf, sdkp, sddjf1a, sdkz, sdde 35010 31/0s sdkr 30010 3 0.5s series soldering temperature soldering time reference for hand soldering reference for dip soldering (for pc board terminal types and sddjf right-angle terminal types) sdkr, sddje, sddjf, sdkp, sdkz, sdde 2605 101s series dip soldering soldering temperature duration of immersion power switches cautions power switches safety standards 1. the primary power supply switching is subject to the safety regulations, and the provisions differ by each destination. consult with us for non-standard use cases. 2. an unstable contact may occur if the switch current is lower than 0.5a. for this case, consult with us. 3. these power switches were produced for alternating current. for direct current, consult with us. 4. appling load to terminals during soldering under certain conditions may cause deformation and electrical property degradation. 5. avoid use of water-soluble soldering flux, since it may corrode the switches. 6. when soldering twice, wait until the first soldered portion cools to normal temperature. continuous heating will deform the external portions, loosen or dislodge terminals, or may deteriorate their electrical characteristics. 7. before soldering switches with locking mechanism, release the locks. if they are soldered without releasing the locks, the soldering heat may deform the locking mechanism. 8. be sure to release the locks before removing the knobs. otherwise, the locking mechanism may be broken. 9. be sure to use the switch with forced travel positioned as close to the total travel as possible. 10 . tighten the mounting screws by applying the specified torque. tightening with a larger torque than the specified will result in malfunction or breakage of screws. 11 . corrosive gas if generated by peripheral parts of a set, malfunction such as imperfect contact may occur. thorough investigation shall be required beforehand. 12 . storage store the products as delivered at normal temperature and humid ity, out of direct sunlight and away from corrosive gases. use them as soon as possible and no later than six months after delivery. once the seal is broken, use them as soon as possible. power switches soldering conditions detector detector slide slide push push rotary rotary power power dual-in-line package type dual-in-line package type rotary type slide type rocker type push type


▲Up To Search▲   

 
Price & Availability of SDKZ1M0200

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X